Pre-Purchase Building Inspection Report
42 Banksia Drive, Casuarina NT 0810
Report No. IAG-2026-0047 | Inspected 15 April 2026
Overall
Serviceable, minor maintenance required
Sections
12 inspected
Photos
14 GPS-verified
Standard
AS 4349.1-2007
Exterior: Roof
Minor DefectThe roof cladding is Colorbond corrugated steel sheeting, estimated age 15-20 years. The sheeting is in serviceable condition overall. Minor surface oxidation was observed on the southern elevation, consistent with age-related weathering. Two fixings on the western ridge cap are lifting and require re-securing to prevent moisture ingress. The roof pitch and drainage appear adequate with no evidence of ponding.
Recommendations
Engage a licensed roofer to re-secure the two lifting ridge cap fixings within 3 months. Monitor oxidation on the southern elevation at the next annual inspection.
Exterior: Walls
Good ConditionExternal walls are double-leaf clay brick veneer construction with a rendered finish on the front elevation. No structural cracking was observed. Expansion joints are present and functioning. Weep holes at the base of the brickwork are clear and unobstructed. The rendered finish shows minor cosmetic crazing consistent with age but no debonding or hollow sections were detected by percussion testing.
Interior: Kitchen
Maintenance RecommendedKitchen benchtops are laminate in serviceable condition. The sink seal has minor separation at the benchtop junction, which may allow moisture penetration if not addressed. Splashback tiles are secure with grout in fair condition. Rangehood extracts to the exterior. Cabinetry is functional with no evidence of pest damage or moisture staining. The dishwasher connection was not tested as part of this inspection.
Recommendations
Re-seal the sink-to-benchtop junction to prevent moisture ingress. Re-grouting of splashback tiles is recommended within 12 months as a maintenance item.
Subfloor
Good ConditionThe subfloor area was accessed and inspected where accessible via the access hatch in the laundry. Ventilation appeared adequate with cross-flow ventilation observed. Ground clearance to bearers is within acceptable limits (minimum 200mm observed). No visible signs of significant timber pest damage, fungal decay, or moisture staining were detected on accessible framing members. Stumps are concrete and appear plumb.